Add STEVAL-MKI217V1 SPI logger and replay
This commit is contained in:
@@ -0,0 +1,110 @@
|
||||
# STEVAL-MKI217V1 polling test (Genesys2)
|
||||
|
||||
This standalone bare-metal application reads the LSM6DSOX on the
|
||||
STEVAL-MKI217V1 over the existing Genesys2 PMOD SPI peripheral. It does not
|
||||
use INT1/INT2. The LIS2MDL magnetometer on the module is not enabled in this
|
||||
first electrical/readout smoke test; it is internally reachable through the
|
||||
LSM6DSOX sensor hub and will be integrated separately after the IMU link is
|
||||
verified.
|
||||
|
||||
## Wiring
|
||||
|
||||
| STEVAL-MKI217V1 | Genesys2 | Function |
|
||||
|---|---|---|
|
||||
| CS | JC1 | active-low chip select |
|
||||
| SDA | JC2 | SPI MOSI / SDI |
|
||||
| SDO | JC3 | SPI MISO |
|
||||
| SCL | JC4 | SPI clock / SPC |
|
||||
| VDD | 3.3 V | sensor supply |
|
||||
| VDDIO | 3.3 V | digital I/O supply |
|
||||
| GND | GND | common ground |
|
||||
|
||||
`CS` is mandatory for four-wire SPI. Never feed 5 V to VDDIO. JC9 is the
|
||||
optional sensor interrupt pin but is deliberately unused here.
|
||||
|
||||
## Hardware bring-up results (2026-07-13)
|
||||
|
||||
The Genesys2/Rocket ELF was loaded over GDB and the UART output was captured
|
||||
on `/dev/ttyUSB0`. All eight identity reads returned `0xff` instead of the
|
||||
expected `0x6c`. In that trial SCL, SDA, SDO, VDDIO, VDD and GND were connected
|
||||
but CS was not. An all-`0xff` response is therefore the expected open/unselected
|
||||
SPI-bus result, not a valid sensor sample.
|
||||
|
||||
After CS was connected to JC1, all eight identity reads returned `0x6c` and
|
||||
configuration read-back returned `CTRL1_XL=0x40`, `CTRL2_G=0x40`,
|
||||
`CTRL3_C=0x44` and `STATUS=0x07`.
|
||||
|
||||
The original FPGA SPI implementation sampled MISO on the data-change edge.
|
||||
A first 60-second diagnostic log consequently contained about 68.4% bit-shifted
|
||||
samples. The generic SPI control register was extended with independent CPOL
|
||||
and CPHA bits while retaining the single/quad-width bit. Mode 0 is selected by
|
||||
this driver and has been verified on hardware. A Mode-3 probe returned an
|
||||
incorrect identity byte (`0x28`), so the CPHA=1 path is not yet production
|
||||
validated.
|
||||
|
||||
One additional LSM6DSOX-specific issue was found: a 14-byte burst crossing the
|
||||
`OUT_TEMP_H` to `OUTX_L_G` internal output-block boundary shifted the remaining
|
||||
stream by one bit. Delaying between bytes did not help. The permanent readout
|
||||
therefore uses a 2-byte temperature burst followed by one coherent 12-byte
|
||||
gyro+accelerometer burst. This is not sample filtering or post-processing; it
|
||||
matches the sensor's output block structure and preserves BDU coherence.
|
||||
|
||||
The final real-hardware capture is
|
||||
`../fusion/logs/steval_mki217v1_clean_60s.csv`:
|
||||
|
||||
- 6349 samples over 59.994462 seconds (105.810 Hz measured)
|
||||
- sequence discontinuities: 0
|
||||
- bit-shifted, saturated or invalid samples: 0
|
||||
- maximum timestamp gap: 4742 CLINT ticks (9.484 ms)
|
||||
- acceleration norm: 9.94245 +/- 0.00687 m/s^2
|
||||
- gyro mean XYZ: +0.20395, -0.07578, -0.27628 deg/s
|
||||
- gyro standard deviation XYZ: 0.02600, 0.02379, 0.02630 deg/s
|
||||
- temperature: 25.909 +/- 0.056 degC
|
||||
|
||||
These measurements are for the stationary board in its test orientation. The
|
||||
nonzero gyro mean is startup bias to be estimated by stationary calibration,
|
||||
not angular motion.
|
||||
|
||||
## Build and load
|
||||
|
||||
From the repository root:
|
||||
|
||||
```sh
|
||||
make FPGA_BOARD=genesys2 fpga-elf-flash-image \
|
||||
APP=steval_mki217v1_test
|
||||
|
||||
make FPGA_BOARD=genesys2 fpga-debug-load \
|
||||
APP=steval_mki217v1_test
|
||||
```
|
||||
|
||||
The default run is 104 Hz for 60 seconds. Alternatives can be passed through
|
||||
the application directory build:
|
||||
|
||||
```sh
|
||||
make -C soc/software/steval_mki217v1_test \
|
||||
BUILD_DIR=../../out/software/steval_mki217v1_test \
|
||||
LSM6DSOX_ODR_HZ=52 CAPTURE_DURATION_S=60
|
||||
```
|
||||
|
||||
Supported smoke-test ODR values are 52, 104 and 208 Hz. At 115200 baud, use
|
||||
52 or 104 Hz for loss-free line-oriented logging. The firmware verifies
|
||||
`WHO_AM_I=0x6c`, selects SPI mode 0, resets the device, enables
|
||||
block-data-update and register auto-increment, and configures +/-2 g and
|
||||
+/-250 dps. The FPGA SPI controller exposes CPOL/CPHA independently from its
|
||||
single/quad data-width selection.
|
||||
|
||||
## UART/replay format
|
||||
|
||||
Each sample is timestamped from the local CLINT/CPU time domain before its SPI
|
||||
burst and emitted without floating-point formatting:
|
||||
|
||||
```text
|
||||
IMU_META,LSM6DSOX,tick_hz=500000,odr_hz=104,accel_ug_lsb=61,gyro_udps_lsb=8750,temp_lsb_c=256,temp_offset_millic=25000
|
||||
IMU_RAW,LSM6DSOX,0,12345678,ax,ay,az,gx,gy,gz,temp
|
||||
```
|
||||
|
||||
Scale factors are 61 ug/LSB, 8750 udps/LSB and 256 LSB/degC with a 25 degC
|
||||
offset. `fusion/fusion_eskf.py` accepts this raw format directly, so a captured
|
||||
log can be replayed with an existing GPS UART capture. Sequential GPS and IMU
|
||||
captures are meaningful only for a stationary test. A moving-platform replay
|
||||
requires GPS and IMU samples stamped in the same firmware/run.
|
||||
Reference in New Issue