Files
pcb/outputs/erc_final_reset.rpt
T
onur 791ca5c9fa Restack the generator and source board to eight layers, matching the deliverable
The routed deliverable has always been eight layers (JLC08161H-3313), but
generate_pcb.py still emitted ten and hardware/board.kicad_pcb was itself still
a ten-layer board. Source and generator agreed with each other and disagreed
with what is actually being fabricated, so running the documented regeneration
flow would have silently replaced the eight-layer design with a conflicting
ten-layer one and destroyed the routing.

generate_pcb.py now builds the real stack: SetCopperLayerCount(8), no L8_PWR /
L9_SIG, and the STACKUP string taken verbatim from board_routed.kicad_pcb - the
two are now byte-identical. Silkscreen reads JLC08161H-3313 8L instead of
JLC10161H 10L, and the title block follows.

The zone layout follows the same correction. With only one dedicated power
plane there is no third plane for the two big FPGA I/O rails, so they are
carried as islands on the routing layers that have room: VCC1V8 on L6 and
VCC3V3 on B.Cu, replacing the ten-layer arrangement of a VCC3V3 background on
L8 and a board-wide GND pour on B.Cu. The regenerated board now reproduces the
routed board's 26 copper zones exactly (the 27th, the F.Cu RF ground pour, is
added later by finalize_routing).

Also drops the In7_Cu/In8_Cu remnants from finalize_routing's RF_NO_DIGITAL
layer set and route_local_power's RF_REGION_LAYERS - those layers do not exist
on this board, so they were dead bits in a layer mask - and corrects the
JLC10161H reference in board.kicad_dru.

The placement check now reports 21 isolated_copper warnings rather than 17.
That is expected and explained in README.md: on an unrouted board the I/O-rail
islands on L6 and B.Cu have nothing joining them yet. The routed board still
reports zero.

Verified: regenerated board is 8 layers with a stackup identical to the routed
board, 312 footprints (311 + R108), TEMP keepouts at their corrected extents.
design_data assertions pass, ERC 0/0, routed board still 0 DRC violations,
0 unconnected, every net one copper group, parity unchanged at 402.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012KaTmCCxCEW4awsmXRNT1d
2026-09-01 13:26:37 +03:00

13 lines
357 B
Plaintext

ERC report (2026-09-01T13:26:17, Encoding UTF8)
Report includes: Errors, Warnings, Exclusions
***** Sheet /
** ERC messages: 0 Errors 0 Warnings 0
** Ignored checks:
- Global label only appears once in the schematic
- Four connection points are joined together
- SPICE model issue
- Assigned footprint doesn't match footprint filters