Complete the routing: 0 DRC violations, 0 unconnected

The board now routes end to end. Every net carrying two or more pads is a
single connected copper group (216 nets, 1175 pads); kicad-cli reports 0 DRC
violations and 0 unconnected items with zones refilled.

Freerouting was never the blocker. The 14 remaining opens were three separate
defects:

1. Obstacles in route_local_power.py modelled every pad as its axis-aligned
   bounding box. A 0.8-mm BGA dogbone site sits diagonally between four lands:
   true clearance 0.1407 mm, but the box test measured 0.4 mm from the box edge
   and rejected it, so no via could be placed anywhere in the Ti375 escape
   field. Replaced with an exact rounded-rectangle model, validated against
   KiCad's own SHAPE::Collide to 0.00 um over 14850 samples. Same 0 DRC and one
   fewer unconnected at the route_local_power stage.

2. CLOCK's 0.15-mm clearance cannot physically escape the BGA: two adjacent
   0.45-mm dogbone vias on 0.8-mm pitch leave a 0.35-mm channel and a 0.10-mm
   trace needs 0.40 mm. HARD_TCK and MAX_SCLK could never leave the package.
   New rule "Ti375 escape field copper clearance" relaxes clearance to the
   0.10 mm this field already uses, only where both objects are inside U1's
   courtyard. The clock trunk keeps 0.15 mm outside it.

3. RF_NO_DIGITAL was a rectangle reaching 7 mm past the RF line, covering the
   MAX2771's whole digital pin field and forcing every U21 output onto F.Cu
   alone. Narrowed to the corridor generate_pcb.py already reserves as
   TEMP_RF_LINE (y <= 43.7), clearing RF copper by 1.1 mm. The RF return path
   is guaranteed by the unrouted L2/L7 ground planes, not by this area.

scripts/close_remaining.py replaces the ad-hoc residual scripts: a multi-layer
maze over (x, y, layer) at 0.1 mm on all five routable layers, seeded from all
copper of both groups, exact clearances, 0.10-mm necking inside the escape
field, and reversible rip-up that rolls back entirely if a displaced net cannot
be put back. ~150 s for the whole board.

Also removes the regenerable intermediate boards, one-off session logs and the
superseded residual scripts, and tracks board_routed.* as the deliverable.

The 402 schematic-parity warnings are pre-existing and unchanged: 199
auto-named unconnected pins, 199 footprint library-nickname mismatches, and 4
mounting holes with no symbol. None affects connectivity or fabrication.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012KaTmCCxCEW4awsmXRNT1d
This commit is contained in:
onur
2026-09-01 11:58:41 +03:00
parent af7c43b2a8
commit 95609a6b6a
33 changed files with 212217 additions and 66530 deletions
+25 -6
View File
@@ -2,21 +2,40 @@
## Giriş yolu
Kartta üç ayrı USB-C/güç konnektörü vardır ve hiçbiri birden fazla rolü
paylaşmaz: `J7` yalnızca USB-C güç girişidir, `J3` yalnızca harici 5 V güç
girişidir, `J1` ise yalnızca JTAG/UART debug portudur ve SYS5'i hiçbir zaman
beslemez.
```text
USB-C VBUS -> U7 TPS259470A (2.69 A typ) -> USB5_PROT --+
+-> U9 TPS2121 -> SYS5
EXT_5V ----> U8 TPS259470A (4.04 A typ) -> EXT5_PROT --+
J7 USB-C VBUS -> U7 TPS259470A (2.69 A typ) -> USB5_PROT --+
+-> U9 TPS2121 -> SYS5
J3 EXT_5V ----> U8 TPS259470A (4.04 A typ) -> EXT5_PROT --+
J1 USB-C VBUS -> yalnızca yerel algılama (U5 VBUS_DET, FTDI_RESET_N bölücüsü);
SYS5'e veya herhangi bir eFuse'a bağlı değil.
```
Her iki eFuse yaklaşık 4.0 V UV ve 5.8 V OV eşiğine, kontrollü output slew'a,
fault test noktasına ve true reverse-current blocking'e sahiptir. U9 4.5 A
limitli power mux'tur; yakın geçerli girişlerde harici 5 V yolu önceliklidir.
Böylece J7 ve J3 aynı anda bağlı olsa bile SYS5 her zaman tek bir kaynaktan
beslenir, ikisi asla toplanmaz.
USB yolunda TUSB320 CC ilanı U10 tarafından decode edilir. `MAIN_EN`, yalnızca
USB kaynağı 3 A ilan ettiğinde veya harici giriş gerçekten U9 tarafından
seçildiğinde yükselir. `VCC3V3_AUX` ise U12 üzerinden SYS5 var olduğu sürece
USB güç yolunda TUSB320 (U35, J7 üzerinde) CC ilanını decode eder ve
`TUSB_OUT1`/`TUSB_OUT2` üzerinden U10'a bildirir. `MAIN_EN`, yalnızca J7 3 A
ilan ettiğinde veya harici giriş gerçekten U9 tarafından seçildiğinde
yükselir. `VCC3V3_AUX` ise U12 üzerinden SYS5 var olduğu sürece
supervisor/debug mantığını besler.
J1'in kendi TUSB320'si (U5) yalnızca CC Rd terminasyonu ve UFP algılaması
için kalır; onun OUT1/OUT2 çıkışları artık hiçbir mantığı sürmez, çünkü J1
gücü hiçbir zaman SYS5'e taşımaz. J1'in VBUS pini yalnızca iki yerel bölücüyü
besler: U5'in `VBUS_DET` girişi ve FT4232H'nin self-powered
`FTDI_RESET_N` algılaması. Böylece FT4232H, J1'e gerçek bir USB host
takılmadığı sürece resette kalır; bu davranış J7 veya J3 üzerinden kart
güçlendirilmiş olsa bile değişmez.
## Ray üretimi
| Sıra | Ray | Regülatör | Nominal kapasite | Yükler |