The board now routes end to end. Every net carrying two or more pads is a
single connected copper group (216 nets, 1175 pads); kicad-cli reports 0 DRC
violations and 0 unconnected items with zones refilled.
Freerouting was never the blocker. The 14 remaining opens were three separate
defects:
1. Obstacles in route_local_power.py modelled every pad as its axis-aligned
bounding box. A 0.8-mm BGA dogbone site sits diagonally between four lands:
true clearance 0.1407 mm, but the box test measured 0.4 mm from the box edge
and rejected it, so no via could be placed anywhere in the Ti375 escape
field. Replaced with an exact rounded-rectangle model, validated against
KiCad's own SHAPE::Collide to 0.00 um over 14850 samples. Same 0 DRC and one
fewer unconnected at the route_local_power stage.
2. CLOCK's 0.15-mm clearance cannot physically escape the BGA: two adjacent
0.45-mm dogbone vias on 0.8-mm pitch leave a 0.35-mm channel and a 0.10-mm
trace needs 0.40 mm. HARD_TCK and MAX_SCLK could never leave the package.
New rule "Ti375 escape field copper clearance" relaxes clearance to the
0.10 mm this field already uses, only where both objects are inside U1's
courtyard. The clock trunk keeps 0.15 mm outside it.
3. RF_NO_DIGITAL was a rectangle reaching 7 mm past the RF line, covering the
MAX2771's whole digital pin field and forcing every U21 output onto F.Cu
alone. Narrowed to the corridor generate_pcb.py already reserves as
TEMP_RF_LINE (y <= 43.7), clearing RF copper by 1.1 mm. The RF return path
is guaranteed by the unrouted L2/L7 ground planes, not by this area.
scripts/close_remaining.py replaces the ad-hoc residual scripts: a multi-layer
maze over (x, y, layer) at 0.1 mm on all five routable layers, seeded from all
copper of both groups, exact clearances, 0.10-mm necking inside the escape
field, and reversible rip-up that rolls back entirely if a displaced net cannot
be put back. ~150 s for the whole board.
Also removes the regenerable intermediate boards, one-off session logs and the
superseded residual scripts, and tracks board_routed.* as the deliverable.
The 402 schematic-parity warnings are pre-existing and unchanged: 199
auto-named unconnected pins, 199 footprint library-nickname mismatches, and 4
mounting holes with no symbol. None affects connectivity or fabrication.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012KaTmCCxCEW4awsmXRNT1d